Anda belum Log-in!
Silahkan Log in

Selamat Datang di Portal Digital Content Publisher
Sabtu , 08 November 2025

Perpustakaan sebagai jantung pendidikan tinggi di Indonesia, harus mampu memberi kontribusi yang berarti bagi pelaksanaan proses belajar mengajar di perguruan tinggi.

TRUNOJOYO » Tugas Akhir & Skripsi » Teknik Mekatronika
di-posting oleh 200491100023 pada 2024-11-08 01:11:40  •  168 klik

Kontrol Arah Gerak Kursi Roda Menggunakan Sistem Electromiography (EMG) Berdasarkan Perbedaan Ketegangan Otot Tangan
Control of Wheelchair Movement Direction Using Electromyography (EMG) System Based on Differences in Hand Muscle Tension

disusun oleh RAHMAT WIJAYA


SubyekSistem Kontrol
Kursi Roda
Sensor EMG
Kata KunciKursi Roda
Sensor EMG
Filter Kalman
Metode PID
Muscle Signal

[ Anotasi Abstrak ]

Sistem kursi roda otomatis semakin mendapatkan perhatian dalam upaya meningkatkan kemandirian dan mobilitas individu dengan keterbatasan fisik. Berdasarkan penjelasan tersebut, penelitian ini difokuskan pada pengembangan kursi roda yang dikendalikan oleh sinyal elektromiography (EMG) menggunakan metode Filter Kalman untuk mengurangi noise dan memprediksi nilai dari sensor EMG. Pergerakan kursi roda menggunakan isyarat kedua tangan gerak biasa dengan meluruskan (ekstensi) untuk berhenti, gerakan menggenggam jari jari kedua tangan untuk gerak maju, gerakan tangan kanan menggenggam dan tangan kiri gerak lurus biasa untuk gerak ke kanan, dan gerakan tangan kiri menggenggam dan tangan kanan gerak lurus biasa untuk gerak ke kiri. Pengujian dilakukan sebanyak 6 percobaan dengan parameter nilai Q dan R pada Filter Kalman yang berbeda. Hasil pengujian mengenai Filter Kalman didapatkan nilai parameter yang terbaik untuk kontrol motor yaitu nilai Q 0,01 dan nilai R 0.08. Parameter tersebut didapatkan dari analisa dari nilai korelasi sensor EMG dan nilai Filter Kalman. Nilai korelasi yang didapatkan sebesar 0,6 dan 0,7 untuk gerak berhenti, 0,6 dan 0, 7 untuk gerak maju, 0,7 dan 0,6 untuk gerak kanan, 0,7 dan 0,8 untuk gerak kiri.


Deskripsi Lain

The automatic wheelchair system is increasingly gaining attention in efforts to enhance the independence and mobility of individuals with physical disabilities. Based on this explanation, this study focuses on the development of a wheelchair controlled by electromyography (EMG) signals using the Kalman Filter method to reduce noise and predict the values from the EMG sensors. The wheelchair's movement is controlled by signals from both hands: extending the arms (extension) to stop, gripping the fingers of both hands to move forward, the right hand gripping and the left hand straight for movement to the right, and the left hand gripping and the right hand straight for movement to the left. Testing was conducted in 6 trials with different Q and R parameter values in the Kalman Filter. The test results for the Kalman Filter indicated that the best parameters for motor control were Q 0.01 and R 0.08. These parameters were determined through an analysis of the correlation between the EMG sensor values and the Kalman Filter values. The correlation values obtained were 0.6 and 0.7 for the stop motion, 0.6 and 0.7 for the forward motion, 0.7 and 0.6 for the right turn, and 0.7 and 0.8 for the left turn.

Kontributor: Ahmad Sahru Romadhon, S. Kom., M. T. Muhammad Latif, S. Kom., M. T.
Tanggal tercipta: 2024-10-23
Jenis(Tipe): Text
Bentuk(Format): pdf
Bahasa: Indonesia
Pengenal(Identifier): TRUNOJOYO-Tugas Akhir-34362
No Koleksi: 200491100023


Sumber :
Universitas Trunojoyo Madura

Ketentuan (Rights) :
23 Oktober 2024

 Download File Penyerta (khusus anggota terdaftar)

 File PDF  1. TRUNOJOYO-Tugas Akhir-34362-Abstract.pdf - 7 KB
 File PDF  2. TRUNOJOYO-Tugas Akhir-34362-Cover.pdf - 693 KB
 File PDF  3. TRUNOJOYO-Tugas Akhir-34362-Chapter1.pdf - 31 KB
 File PDF  4. TRUNOJOYO-Tugas Akhir-34362-Chapter2.pdf - 571 KB
 File PDF  5. TRUNOJOYO-Tugas Akhir-34362-Chapter3.pdf - 742 KB
 File PDF  6. TRUNOJOYO-Tugas Akhir-34362-Chapter4.pdf - 1204 KB
 File PDF  7. TRUNOJOYO-Tugas Akhir-34362-Conclusion.pdf - 8 KB
 File PDF  8. TRUNOJOYO-Tugas Akhir-34362-References.pdf - 75 KB
 File PDF  9. TRUNOJOYO-Tugas Akhir-34362-Appendices.pdf - 261 KB


 Dokumen sejenis...

     Tidak ada !

 Dokumen yang bertautan...





 Kembali ke Daftar